FRABO 4000 fittings are suitable for a big number of applications both in civil and industrial installations: drinking water, heating and cooling systems, gas distribution systems, chilled water, compressed-air and solar installations.
 | Fields of application | Pmax (bar) |
Tmin-Tmax |
---|---|---|---|
|
25 bar, -20°/+30°C (ø ≥ 6mm ≤ 54mm) 16 bar, -20°/+30°C (ø > 54mm ≤ 108mm) 25 bar, +31°/+65°C (ø ≥ 6mm ≤ 34mm) 16 bar, +31°/+65°C (ø > 34mm ≤ 108mm) 16 bar, +66°/+110°C (ø ≥ 6mm ≤ 34mm) 10 bar, +66°/+110°C (ø > 34mm ≤ 108mm) |
||
![]() |
16 bar, 30°C  (ø ≥ 6mm ≤ 54mm) 10 bar, 30°C (ø > 54mm ≤ 108mm) |
||
![]() |
Gas | 5 | 70°C |
![]() |
Solar | Â | Â |
![]() |
Industrial installations | Â | Â |
Maximum pressures and working temperatures are in accordance with EN 1254-1. Pressures are defined considering as joining method Brazing (EN ISO 17672).
For use in applications outside the scope of this table, the advice of the manufacturer should be asked. Intermediate pressure ratings shall be obtained by interpolation. Contact tech dept for further information.